Harmonic Compensation of Distribution generation Using Photovoltaic Interfacing Inverter

Thulluri Shiva, N Vijayakumar

Abstract


Normally increasing utilization of electronic devices in homes leads the researchers to concentrate on harmonic problem Besides the degrading power quality, the harmonic current flow may interfere with the adjacent telephone lines. The harmonics in a residential system is difficult because of the dispersed nature of the residential loads.

This worktried to improve the power quality using distributed generation system in residential areas. To compensate a harmonics resonance in residential areas, active and passive filters are used in distribution network. To improve the distribution generation (DG) using photovoltaic interface inverter the harmonics was compensated.


References


J. Arrillaga and N. R. Watson, Power System Harmonics, 2nd ed.Hoboken, NJ, USA: Wiley, 2003, pp. 176–180.

K. Wada, H. Fujita, and H. Akagi, Considerations of a shunt activefilter based on voltage detection for installation on a long distributionfeeder,” IEEE Trans. Ind. Appl., vol. 38, no. 4, pp. 1123–1130,

July/Aug 2002.

European Photovoltaic Industry Association (EPIA) “Annual report2011”, Mar. 2012, pp. 5–7.

Global Wind Energy Council (GWEC) “Global wind report, annualmarket update 2011”, Mar. 2012, pp. 4–7.

M. Triggianese, F. Liccardo, and P. Marino,“Ancillary services performedby distributed generation in grid integration,” in Proc. IEEE

Int. Conf. Clean Electr. Power, 2007, pp. 164–170.

M. I. Marei, T. K. Abdel-Galil, E. F. El-Saadany, and M. M. A.Salama, “Hilbert transform based control algorithm of the DG interfacefor voltage flicker mitigation,” IEEE Trans. Power Del.,vol.20,

pp. 1129–1133, Apr. 2005.

.Prodanovic,K.D.Brabandere,J.V.D.Keybus,T.Green,andJDriesen, “Harmonic and reactive power compensation as ancillary servicesin inverter-based distributed generation,” in IEE Proc. Gener.

Transm.Distrib., May 2007, vol. 1, pp. 432–438.

Y. W. Li, D. M. Vilathgamuwa, and P. C. Loh, “Microgrid powerquality enhancement using a three-phase four- wire grid-interfacingcompensator,” IEEE Trans. Ind. Appl., vol. 41, pp. 1707–1719, Nov.

–Dec. 2005.

C.H.Lin,W.L.Hsieh,C.S.Chen,C.T.Hsu,andT.T.Ku,“Optimizationof photovoltaic penetration in distribution systems consideringannual duration curve of solar irradiation,” IEEE Trans. PowerSyst., vol. 27, no. 2, pp. 1090–1097, May 2012.

A. Capasso, W. Grattieri, R. Lamedica, and A. Prudenzi, “A bottom-upapproach to residential load modeling,” IEEE Trans. Power Syst., vol.

, no. 2, pp. 957–964, May 1994.


Full Text: PDF[FULL TEXT]

Refbacks

  • There are currently no refbacks.


Copyright © 2013, All rights reserved.| ijseat.com

Creative Commons License
International Journal of Science Engineering and Advance Technology is licensed under a Creative Commons Attribution 3.0 Unported License.Based on a work at IJSEat , Permissions beyond the scope of this license may be available at http://creativecommons.org/licenses/by/3.0/deed.en_GB.