UPQC Implements The 3-Phase Shunt And Series Active Power Filter To Compensate Current And Voltage Harmonics

J. Sunitha, M. Ramesh

Abstract


This paper presents the three phase shunt and series active power filter in order to reduce the current and voltage harmonics. To implement Unified Power Quality Conditioner (UPQC) control algorithm two control strategies p-q instantaneous power and d-q synchronous frame theory are used to mitigate the problems of power quality caused due to nonlinear loads. Both control theories performances are carried out and compared under nonlinear loads. The performance of UPQC with two control strategies has been tested in the Matlab/Simulink environment. The simulation results showed better performance for harmonic problems

References


M. Cirrincione, M. Pucci, G. Vitale, and A.

Miraoui, “Current harmonic compensation by

a single-phase shunt active power filter

controlled by adaptive neural filtering,” IEEE

Transactions on Industrial Electronics, vol. 56,

no. 8, pp. 3128 3143, 2009.

P. Salmeron and S. Litran, “Improvement of

the electric power quality using series active

and shunt passive filters,” IEEE Transactions

on Power Delivery, vol. 25, no. 2, pp. 1058–

, 2010.

H. Hu, W. Shi, Y. Lu, and Y. Xing, “Design

considerations for DSPcontrolled 400 Hz shunt

active power filter in an aircraft power

system,”

IEEE Trans. Ind. Electron., vol. 59,

no. 9, pp. 3624–3634, Sep. 2012.

X. Du, L. Zhou, H. Lu, and H.-M. Tai, “DC

link active power filter for three-phase diode

rectifier,”

IEEE Trans. Ind. Electron., vol. 59,

no. 3,pp. 1430–1442, Mar. 2012.

M. Angulo, D. A. Ruiz-Caballero, J. Lago, M.

L. Heldwein, and S. A. Mussa, “Active power

filter control strategy with implicit closedloop

current control and resonant controller,”

IEEE

Trans. Ind. Electron.

, vol. 60, no. 7, pp. 2721–

, Jul. 2013

H. Akagi, E. H. Watanabe, and M. Aredes,

“Instantaneous power theory and applications

to power conditioning,” Hoboken, NJ: WileyIEEE

Press, Apr. 2007.

H. Fujita and H. Akagi, “The unified power

quality conditioner: The integration of series

and shunt active filters,” IEEE Trans. Power

Electron., vol. 13, no. 2, pp. 315–322, Mar.

Teke, L. Saribulut and M. Tümay, “A novel

reference signal generation method for power

quality improvement of unified power quality

conditioner,” IEEE Trans. Power Del., Vol. 26,

no. 4, pp. 2205-2214, Oct. 2011.

Tan Zhili, Li Xun, Chen Jian, Kang Yong and

Duan Shanxu, “A direct control strategy for

UPQC in three-phase four-wire system,” Proc.

IEEE Conf. on Power Electronics and Motion

Control 2006, vol.2, pp.1-5.

V. Khadkikar, “Enhancing Electric Power

Quality Using UPQC: A comprehensive

overview,” IEEE Trans. Power Electron. Vol.

, No.5, pp.2284 – 2297, May 2012

.


Full Text: PDF [Full Text]

Refbacks

  • There are currently no refbacks.


Copyright © 2013, All rights reserved.| ijseat.com

Creative Commons License
International Journal of Science Engineering and Advance Technology is licensed under a Creative Commons Attribution 3.0 Unported License.Based on a work at IJSEat , Permissions beyond the scope of this license may be available at http://creativecommons.org/licenses/by/3.0/deed.en_GB.