Control of a Three-Phase DC-AC Converter With an Unbalanced AC Source

Meleti Sobhana Satish kumar, G Venkateswara Rao

Abstract


Three-stage dc–ac control converters experience the ill effects of energy swaying and over current issues if there should be an occurrence of the uneven air conditioning source voltage that can be caused by matrix/generator issues. Existing techniques to deal with these issues are legitimately choosing and controlling the positive-and negative-arrangement streams. In this venture, another arrangement of control techniques which use the zero grouping segments are proposed to improve the power controllability under this antagonistic condition. It is reasoned that by presenting legitimate zero-arrangement current controls and comparing circuit designs, the power converter can empower more adaptable control targets, accomplishing better exhibitions in the conveyed control and the heap current when experiencing the unequal voltage. fluffy controller is utilized for the better smoothening of yield wave shapes. Recreation results are exhibited to check the attainability of the proposed approach in MATLAB/SIMULINK condition.

 


References


F. Blaabjerg, M. Liserre, and K. Ma, “Power controllability of a three phase unbalanced ac source,” IEEE Trans. Ind. Appl., vol. 48, no. 2, pp. 708–719, Mar./Apr. 2012.

R. Teodorescu, M. Liserre, and P. Rodriguez, Grid Converters for Photovoltaicand Wind Power Systems. New York, NY, USA: Wiley-IEEE,2011.

J. Rocabert, G. M. S. Azevedo, A. Luna, J. M. Guerrero, J. I. Candela, andP. Rodriguez, “Intelligent connection agent for three-phase grid-connectedmicrogrids,” IEEE Trans. Power Electron, vol. 26, no. 10, pp. 2993–3005,Oct. 2011.

J. W. Kolar and T. Friedli, “The essence of three-phase PFC rectifiersystems—Part I,” IEEE Trans. Power Electron., vol. 28, no. 1, pp. 176–198, Jan. 2013.

J. Hu, L. Shang, Y. He, and Z. Z. Zhu, “Direct active and reactive powerregulation of grid-connected dc/ac converters using sliding mode controlapproach,” IEEE Trans. Power Electron., vol. 26, no. 1, pp. 210–222, Jan.2011.

C. Wessels, F. Gebhardt, and F. W. Fuchs, “Fault ride-through of a DFIGwind turbine using a dynamic voltage restorer during symmetrical andasymmetrical grid faults,” IEEE Trans. Power Electron., vol. 26, no. 3,pp. 807–815, Mar. 2011.

F. Aghili, “Fault-tolerant torque control of BLDC motors,” IEEE Trans.Power Electron., vol. 26, no. 2, pp. 355–363, Feb. 2011.

Y. Xiangwu, G. Venkataramanan, W. Yang, D. Qing, and Z. Bo, “Gridfaulttolerant operation of a DFIG wind turbine generator using a passiveresistance network,” IEEE Trans. Power Electron., vol. 26, no. 10,pp. 2896–2905, Oct. 2011.

B. A. Welchko, T. A. Lipo, T. M. Jahns, and S. E. Schulz, “Fault tolerantthree-phase AC motor drive topologies: A comparison of features, cost,and limitations,” IEEE Trans. Power Electron., vol. 19, no. 4, pp. 1108–1116, Jul. 2004.


Full Text: PDF [Full Text]

Refbacks

  • There are currently no refbacks.


Copyright © 2013, All rights reserved.| ijseat.com

Creative Commons License
International Journal of Science Engineering and Advance Technology is licensed under a Creative Commons Attribution 3.0 Unported License.Based on a work at IJSEat , Permissions beyond the scope of this license may be available at http://creativecommons.org/licenses/by/3.0/deed.en_GB.