Direct Power Control Algorithm for Electric Traction Systems

M Bala manikanta, M Uma rani

Abstract


In this paper presents a direct power control-based algorithm is used for general filtering and unbalance compensation scheme for electric traction systems. This method can improve the power flow exchange between the grid and the load . As a result unbalanced load is seen as a balanced linear load. The proposed filter is evaluated on power substations for two-level and dual-converter in the power stage. This method is experimented simulated and shown a better oerformance.


References


B. K. Chen and B. S. Guo, “Three phase models of specially connected transformers,” IEEE Trans. Power Del., vol. 11, no. 1, pp. 323–330, Jan.1996.

G. W. Chang, H. W. Lin, and S. K. Chen, “Modeling characteristics of harmonic currents generated by high-speed railway traction drive converters,” IEEE Trans. Power Del., vol. 19, no. 2, pp. 766–733, Apr. 2004.

R. E. Morrison, “Power quality issues on ac traction systems,” in Proc.9th Int. Conf. Harmon. Quality Power, 2000, vol. 2, pp. 709–714.

Z. Sun, X. Jiang, D. Zhu, and G. Zhang, “A novel active power quality compensator topology for electrified railway,” IEEE Trans. Power Electron.,vol. 19, no. 4, pp. 1036–1042, Jul. 2004.

S. T. Senini and P. J. Wolfs, “Novel topology for correction of unbalanced load in single phase electric traction systems,” in Proc. IEEE 33rd Annu.Power Electron.Special. Conf., 2002, vol. 3, pp. 1208–1212.

M. Goto, T. Nakamura, Y. Mochinaga, and Y. Ishii, “Static negative-phasesequence current compensator for railway power supply system,” in Proc. Int. Conf. Electr. Railways United Eur., Mar. 1995, pp. 78–82.

P. Xiao, K. A. Corzine, and G. K. Venayagamoorthy, “Multiple reference frame-based control of three-phase PWM boost rectifiers under unbalanced and distorted input conditions,” IEEE Trans. Power Electron., vol. 23, no. 4, pp. 2006–2017, Jul. 2008.

P. Lohia, M. K. Mishra, K. Karthikeyan, and K. Vasudevan, “A minimally switched control algorithm for three-phase four-leg VSI topology to compensate unbalanced and nonlinear load,” IEEE Trans. Power Electron., vol. 23, no. 4, pp. 1935–1944, Jul. 2008.

F. Wang, J. Duarte, and M. Hendrix, “Pliant active and reactive power control for grid-interactive converters under unbalanced voltage dips,” IEEE Trans. Power Electron., vol. 26, no. 5, pp. 1511–1521, May 2011.

C. Wu, A. Luo, J. Shen, F. J. Ma, and S. Peng, “A negative sequence compensation method based on a two-phase three-wire converter for a high-speed railway traction power supply system,” IEEE Trans. Power Electron., vol. 27, no. 2, pp. 706–717, Feb. 2012.

J. M. Aller, A. Bueno, and T. Pag a, “Power system analysis using space vector transformation,” IEEE Trans. Power Syst., vol. 17, no. 4, pp. 957–965, Nov. 2002.

H. Li, F. Zhuo, L. Wu, W. Lei, J. Liu, and Z. Wang, “A novel current detection algorithm for shunt active power filters in harmonic elimination, reactive power compensation and three-phase balancing,” in Proc. IEEE 35th Annu. Power Electron.Special.Conf., Jun. 2004, vol. 2, pp. 1017– 1023.

M. Aredes, H. Akagi, E. H. Watanabe, E. Vergara Salgado, and L. F. Encarnacao, “Comparisons between the p-q and p-q-r theories in three-phase four-wire systems,” IEEE Trans. Power Electron., vol. 24, no. 4, pp. 924–933, Apr. 2009.

L. S. Czarnecki, “Instantaneous reactive power p-q theory and power properties of three-phase systems,” IEEE Trans. Power Del., vol. 21, no. 1,pp. 362–367, Jan. 2006.


Full Text: PDF[FULL TEXT]

Refbacks

  • There are currently no refbacks.


Copyright © 2013, All rights reserved.| ijseat.com

Creative Commons License
International Journal of Science Engineering and Advance Technology is licensed under a Creative Commons Attribution 3.0 Unported License.Based on a work at IJSEat , Permissions beyond the scope of this license may be available at http://creativecommons.org/licenses/by/3.0/deed.en_GB.